HVAC Fundamentals by Samuel C. Sugarman

By Samuel C. Sugarman

This grasp quantity covers the complete diversity of HVAC structures utilized in brand new amenities. finished in scope, the textual content is meant to supply the reader with a transparent knowing of ways HVAC platforms function, in addition to the best way to choose the perfect method and approach elements to accomplish optimal functionality and potency for a specific program. you will study the explicit ways that every one procedure, subsystem or part contributes to delivering the specified indoor setting, in addition to what components impact power conservation, indoor air caliber and price. tested intimately are compressors, water chillers, fanatics and fan drives, air distribution and variable air quantity, pumps and water distribution, controls and their parts, warmth restoration, and effort conservation techniques. additionally lined are warmth circulation basics, in addition to warmth movement calculations utilized in identifying apparatus and picking approach working functionality and prices.

Show description

Read or Download HVAC Fundamentals PDF

Best ventilation & air conditioning books

Practical Soil Dynamics: Case Studies in Earthquake and Geotechnical Engineering

The target of this booklet is to fill a few of the gaps within the present engineering codes and criteria concerning soil dynamics, pertaining to matters in earthquake engineering and floor vibrations, through the use of formulation and hand calculators. The usefulness and accuracy of the easy analyses are validated by way of their implementation to the case histories to be had within the literature.

Meccanica delle strutture e controllo attivo strutturale: Modellistica di edifici, ponti, camini, strutture speciali

I testi di base di Ingegneria delle Strutture, presenti in letteratura, danno in keeping with lo più esempi introduttivi. Questo testo, invece, dopo aver dato i fondamenti disciplinari, va oltre in keeping with guidare il lettore nella costruzione di modelli matematici avanzati. .. E' un inedito "compromesso" tra testo di teoria di base e testo avanzato according to advanced-professionals e ricercatori.

Extra info for HVAC Fundamentals

Sample text

The difference of 45,360 Btuh (243,810–198,450) is the additional heat required for the outside air. 08 × 40 TD (70-30) LAT - leaving air temperature (coil). 08 × 5250) Answer: 43°F TD (62 EAT + 43 TD = 105 LAT) 243,810 Btuh is the Sensible Coil Heating Load. 08 × 43 TD (105-62) The mixed air temperature (MAT also called EAT) was calculated using this equation: MAT = (%OA × OAT) + (%RA × RAT) Where: MAT = mixed air temperature OAT = outside air temperature RAT = return air temperature, also called room air temperature 44 HVAC Fundamentals Then: MAT = (20% × 30°F) + (80% × 70°F) MAT = (6) + (56) Answer: MAT = 62 °F VENTILATING SYSTEMS In occupied buildings, carbon dioxide, human odors and other contaminants such as volatile organic compounds (VOC) or odors and particles from machinery and the process function need to be continuously removed or unhealthy conditions will result.

The change in the sensible heat level as measured with an ordinary thermometer is sensible temperature. Sensible temperature is measured in degrees Fahrenheit (°F) and it is indicated as dry bulb (db) temperature. Sensible temperatures are written °Fdb. For example, 55°Fdb. ” The heat released by boiling water is an example of latent heat. Once water is brought to the boiling point, adding more heat only makes it boil faster; it does not raise the temperature of the water. The level of latent heat is measured in degrees Fahrenheit (°F) and it is indicated as dew point (dp) temperature (for example, 60°Fdp).

Oil burners are classified by how they prepare the oil for burning such as vaporizing, atomizing or rotary. Oil burners use the same methods of delivering air to the combustion chamber as do gas burners. They are either natural-, forcedor induced-draft. Regardless of what type of burner is used, proper combustion depends on the correct ratio of fuel-to-air. FUEL-TO-AIR RATIOS A high fuel-to-air ratio causes sooting and lowers boiler efficiency. In certain conditions, it may also be dangerous if there’s not enough air for complete combustion and dilution of the fuel.

Download PDF sample